LCE Post Cap

Model: LCE

{{ formattedPrice }} inc. GST {{ productData.list_price }}
{{ stock.company }} Qty: {{ stock.total_quantity }}
SKU: {{ sku }}
UOM Qty: {{ uomQty }}
{{ quantity }} exceeds {{ totalQuantity }} in stock – will be backordered 这里要加backorder时长 从产品数据内取.

Post caps connect tops of posts to members for a secure connection and are ideal for new or retrofit applications where structural support is needed. The LCE is designed to provide a connection when the end of a beam bears on a post. This versatile, two-piece product can accommodate 90mm or 140mm timber and features a universal design that eliminates right and left versions.

Please check the Corrosion Information to see if it is suitable for your application.

Material

Carbon Steel 1mm thick

Finish

Z275 Galvanised

Features & Benefits
  • Eliminates the need to nail into the end grain of the post
  • Stronger than toenailing or screw fastening; eliminates nailing into end grain
  • Engineered swages for extra strength and to minimise deflections
  • Suitable for 90mm-140mm timber width
Installation
  • Use all specified fasteners 
  • 90mm (min.) timber width
  • Must be installed in pairs
 
 
Model No. Table

Model No.

Dimensions (mm)

Fasteners
(No. – Length x Dia., mm)

Design Capacity (kN)

H

B

Beam

Post

Uplift
k1 = 1.0

Lateral
k1 = 1.0

LCE4

135

135

14 – 75 x 3.75

10 – 75 x 3.75

6.95

7.44

  1. Design Capacity is the lesser of (1) the Characteristic Capacity multiplied by the NZ Strength Reduction Factor (φ), and applicable the k modification factors following NZS 3603 and (2) the Serviceability Capacity which is the load at 3.2mm joint slip. Design Capacity is the minimum of test data and structural joint calculation.
  2. The Strength Reduction Factor (φ) is 0.80 for nails in lateral loading.
  3. Duration of Load Factor (k1) is as shown. Reduce Duration of Load Factor where applicable. Capacities may not be increased.
  4. Timber species for joint design is seasoned Radiata Pine, which is New Zealand Joint Group J5 per NZS 3603 Table 4.1.
  5. LCE4 Design Uplift Capacity for mitered corner conditions is 8.31 kN for NZ. Lateral loads do not apply.
  6. Loads only apply when used in pairs.
  7. Structural composite timber columns have sides that either show the wide face or the edges of the timber strands/ veneers, known as the narrow face.
    Values in the table reflect installation into the wide face.
 